"Instant linkage device for voltage over-limit warning" published in "Instrument Technology" Issue 4, 2020
In view of the lag in obtaining information from field managers in the current grid voltage monitoring, and there is no real-time adjustment mechanism for over-limit voltage, this paper establishes a set of DCBZ (voltage over-limit alarm device) and management procedures, which have the conditions to monitor voltage changes in voltage lines around the clock. Short messages are sent out through DCBZ on-site, which are identified by the data center and notified by SMS when the warning point is reached, and then the corresponding voltage adjustments are made, which provides a more convenient means for the improvement of power voltage management.
See more information
In view of the lag in obtaining information from field managers in the current grid voltage monitoring, and there is no real-time adjustment mechanism for over-limit voltage, this paper establishes a set of DCBZ (voltage over-limit alarm device) and management procedures, which have the conditions to monitor voltage changes in voltage lines around the clock. Short messages are sent out through DCBZ on-site, which are identified by the data center and notified by SMS when the warning point is reached, and then the corresponding voltage adjustments are made, which provides a more convenient means for the improvement of power voltage management.
"Online Monitoring and Governance of Harmonics" is published in "Electrical Application" Issue 5, 2020
A specific description of a set of intelligent harmonic online monitoring and management system established for the harmonic problem of power users. The on-site GPRS multi-functional harmonic monitor at the monitoring point samples, stores and actively uploads the harmonic data, the gateway and the client identify and process the harmonic data, and the system master station releases the harmonic data and analyzes the treatment method according to the treatment method Optimizing and installing harmonic control equipment at the monitoring point. The Android APP compares the harmonic data and optimizes the parameters of the harmonic control equipment to form a complete closed-loop system, which provides an effective means for power harmonic control.
See more information
A specific description of a set of intelligent harmonic online monitoring and management system established for the harmonic problem of power users. The on-site GPRS multi-functional harmonic monitor at the monitoring point samples, stores and actively uploads the harmonic data, the gateway and the client identify and process the harmonic data, and the system master station releases the harmonic data and analyzes the treatment method according to the treatment method Optimizing and installing harmonic control equipment at the monitoring point. The Android APP compares the harmonic data and optimizes the parameters of the harmonic control equipment to form a complete closed-loop system, which provides an effective means for power harmonic control.
"Harmonic Control of Hot Die Casting Enterprises" is published in "Instrument Technology" Issue 2, 2020
Use modern network communication technology to transform the monitoring, analysis and control methods of power system harmonics. This harmonic monitoring terminal management system accurately monitors the harmonics of the power grid and other power parameters, uses network communication means, uploads the data to the computer host for scientific analysis, and can synchronize the analysis results to the mobile phone terminal for power harmonic monitoring Provide effective technical support. The operation of several pilots shows the effectiveness of the system.
See more information
Use modern network communication technology to transform the monitoring, analysis and control methods of power system harmonics. This harmonic monitoring terminal management system accurately monitors the harmonics of the power grid and other power parameters, uses network communication means, uploads the data to the computer host for scientific analysis, and can synchronize the analysis results to the mobile phone terminal for power harmonic monitoring Provide effective technical support. The operation of several pilots shows the effectiveness of the system.
"Application of Voltage and Current Real-time Monitoring Device in Railway Station Yard Power Supply" published in "Electrified Railway" Issue 6, 2017
In order to obtain the voltage and current information on the spot in time, and realize the effective monitoring of the voltage and current of the railway station power supply, the development of the real-time voltage and current monitoring management system and the voltage and current monitoring management for the station are implemented. Through nearly 3 years of application practice and continuous improvement, the monitoring effect is remarkable.
See more information
In order to obtain the voltage and current information on the spot in time, and realize the effective monitoring of the voltage and current of the railway station power supply, the development of the real-time voltage and current monitoring management system and the voltage and current monitoring management for the station are implemented. Through nearly 3 years of application practice and continuous improvement, the monitoring effect is remarkable.
"Voltage Monitoring in Light Source Life Test Testing" was published in "Light Source and Lighting" Issue 3, 2017
Starting from the test requirements in the life test of the light source, the current power quality of the mains power supply, the voltage fluctuation of the power supply, the power supply voltage test requirements in the life test of the light source, the improvement of the means of monitoring the power supply to the test state, and the life test of the light source Insufficiency, deepen the discussion on improving the life test method of light source, so as to have a deeper understanding of the limited conditions of light source life test detection.
See more information
Starting from the test requirements in the life test of the light source, the current power quality of the mains power supply, the voltage fluctuation of the power supply, the power supply voltage test requirements in the life test of the light source, the improvement of the means of monitoring the power supply to the test state, and the life test of the light source Insufficiency, deepen the discussion on improving the life test method of light source, so as to have a deeper understanding of the limited conditions of light source life test detection.
"Research and Application of Information Management System for Voltage Quality Monitoring in Substations" published in "China Chemical Industry Trade", Issue 34, 2017
This article introduces the substation voltage quality monitoring information management system organized and developed by Dagang Oilfield Power Company. The system adopts a three-tier architecture and supports B/S and C/S modes. The data communication software adopts C/S architecture and accepts communication dispatch from the WEB terminal. The background service sends communication instructions to the on-site monitor, and at the same time processes the monitoring data sent back by the monitor, and saves it in the database, and then uses the application to perform data storage, analysis and statistics, fault alarms, report generation, and automatically store the data in the operation and maintenance database . Relevant personnel can set relevant parameters, maintain various data, and dispatch communications through IE browser
See more information
This article introduces the substation voltage quality monitoring information management system organized and developed by Dagang Oilfield Power Company. The system adopts a three-tier architecture and supports B/S and C/S modes. The data communication software adopts C/S architecture and accepts communication dispatch from the WEB terminal. The background service sends communication instructions to the on-site monitor, and at the same time processes the monitoring data sent back by the monitor, and saves it in the database, and then uses the application to perform data storage, analysis and statistics, fault alarms, report generation, and automatically store the data in the operation and maintenance database . Relevant personnel can set relevant parameters, maintain various data, and dispatch communications through IE browser
Accept the sixth review of the quality management system
2020 is the 19th anniversary of the establishment of our quality system. In late April, the company entered the sixth review of the quality management system. Because it is still in the period of strict prevention and control of the new crown pneumonia epidemic, our company has not accepted ordinary challenges.
See more information
2020 is the 19th anniversary of the establishment of our quality system. In late April, the company entered the sixth review of the quality management system. Because it is still in the period of strict prevention and control of the new crown pneumonia epidemic, our company has not accepted ordinary challenges.