搜索
Search
Confirm
Cancel
shunyang
Number of views:
1000
Detail
Parameters

SYEZ11 multifunctional harmonic monitor can continuously and effectively collect, store and count voltage, the effective value of voltage fundamental wave and the content of 2-31 harmonics. It is used for electric power, automobile, metallurgy, machinery manufacturing, chemical industry, papermaking, textile, coal , Shipbuilding, communications, airports, large venues, high-rise buildings and other important places to control harmonic pollution to provide reliable monitoring data.

The high-end harmonic monitor with 32-bit ARM as the core is suitable for power users' collection, storage, statistics, display, transmission, analysis and other fields of grid harmonic data. It is an independent harmonic monitoring designed for networked management. Device. The modular design of the communication terminal, combined with the voltage quality information management system that complies with the "Shunyang Power Quality Monitor Communication Protocol", realizes the command interaction between the CAC and the device and the active reporting of device data, which is an ideal harmonic monitoring Instrument upgrade products.

1. Product standard:

GB/T 14549-93 Power quality public grid harmonics

GB/T 19862-2005 General requirements for power quality monitoring equipment

DL/T 1227-2013 Technical specification for power quality monitoring device

DL500-2009 Voltage Monitor Technical Specification

2. Multifunctional module combination:

▶Data storage function

▶Display function

▶Parameter setting and query function

▶Clock and time synchronization function

▶Communication function

▶Self-check and self-recovery function

▶Function status setting

▶Keyboard function

▶Device key response function

3. Performance indicators:

▶Power input: AC/DC 60V~480V

▶Sampling input: phase voltage: 57.7V, 220V

▶Phase current: 1A, 5A ▶Power loss:

Power supply: ≤5VA

Sampling: ≤0.5VA

▶Clock error:

The clock error is less than or equal to 1s/d, and the normal running time can be maintained for more than 50,000h after power failure (from the day when the monitoring meter leaves the factory).

▶Accuracy:

Voltage: ≤0.2%

Current: ≤0.2%

Active power: ≤0.5%

Reactive power: ≤0.5%

Apparent power: ≤0.5%

▶Power factor: 2%

Harmonic: Class B

▶Storage capacity:

32k ferroelectric memory, 32MFlash.

Mean time between failures: MTBF≥50000h

▶Protection measures:

The whole machine has passed the following seven electromagnetic compatibility tests: electrostatic discharge immunity test, electromagnetic field radiation immunity test, electrical fast transient pulse group immunity test, surge (impact) immunity test, power frequency magnetic field immunity test Disturbance test, damped shock wave immunity test and voltage sag short-term interruption immunity test, etc.

▶Shell protection performance:

Adopt IP52 protection grade, sealed design, dustproof, waterproof splash, wall-mounted installation.

▶Flame-retardant performance: The flame-retardant performance of the non-metallic shell and terminal block meets the flame-retardant requirements of GB/T 5169.11.

▶Use environment:

Ambient temperature: -10℃~+50℃ Limit temperature: -25℃~+70℃

Relative humidity: 40℃(20~90)%RH

Atmospheric pressure: 70~106kPa

▶Overload capacity:

Voltage signal circuit: continuous 1.2 times the rated voltage, can withstand 2 times the rated voltage/s instantly.

Current signal circuit: continuous 1.2 times the rated current, can withstand 10 times the rated voltage/s instantly.

▶Insulation resistance and power frequency withstand voltage:

Insulation resistance: ≥5MΩ

Power frequency withstand voltage: power supply/input/output 2.5kV, lasting 1min, leakage current 0.4mA.

▶Dimensions: Hanging type (/G): 226×160×67mm (length×width×thickness).

▶Weight: 1.3kg (1.5kg when built-in GPRS module).

▶Wiring mode: three-phase four-wire; terminal definition.

▶Communication method: RS232\RS485\GPRS\LAN.

Product number:

Model number Specification Wiring method Sampling voltage Current Installation form Power supply

SYEZ11

3×100V/G

Three-phase four-wire

AC57.7V、220V

5A

Hang

AC/DC(60~480)V

Three-phase four-wire

100V

3×100(380)V/G

Three-phase four-wire

AC57.7V、220V

5A

Three-phase four-wire

AC100V、380V

 

We could not find any corresponding parameters, please add them to the properties table